Code: 6902
Description: Rechecking the error after the power switch was turned OFF and then ON again because an error was detected in the fuser unit. (This message is displayed for approximately 15 minutes when the machine is restarted after error code 6901 has occurred.)
Remedy: 1 Connection failure of a fuser unit harness Reconnect the fuser unit harness. 2 Connection failure of the eject sensor harness Reconnect the eject sensor harness. 3 Eject sensor PCB failure Replace the eject sensor PCB ASSY. 4 Fuser unit failure Replace the fuser unit. 5 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY. Note: • Turn OFF the power switch. After the fuser unit has cooled sufficiently, turn ON the power switch again and leave the machine for 15 minutes. This problem may then be cleared. • To release the fuser unit error after taking appropriate measures, enter the maintenance mode once and quit it with the function code 99.