Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 142-xx — Lexmark C532dn

Code: 142-xx

Description: Motor Error
Fuser motor has failed.
Remedy: 1 Turn the printer off and remove the rear cover. Check connector JFUSER1 for proper connection to system card, cable for pinch points and cable or connector for any other damage. Is cable properly connected and damage free? Go to step 2. If connector is damaged on system card, replace system card. Go to “System card removal”. If fuser cable is damaged, replace cable.
2 Turn printer power on and check for 24 V dc between JCVR1 pin 1 (red wire) and ground. Is voltage present? Note: Ground lead of voltmeter can be placed on metal chasis to obtain ground. Go to step 3. Disconnect JCVR1 and check for 24 V dc between pin 1 of system card connector and ground. If voltage is present, replace 24V interlock switch.Go to “Top access door 24V interlock switch removal”. If voltage is not present, replace system card. Go to “System card removal”.
3 Reconnect JCVR1 if disconnected. Ensure top access door is completely closed. Check for 24 V dc between JCVR1 pin 2 (white wire) and ground. Is voltage present? Go to step 4. Replace 24V interlock switch. Go to “Top access door 24V interlock switch removal”
4 Replace fuser. Go to “Fuser removal”. Does error clear? Problem solved. Replace system card. Go to “System card removal”.