Code: 122.13
Description: Service Fuser Error
Fuser open thermistor check failed forsecond thermistor.
Fuser open thermistor check failed forsecond thermistor.
Remedy: 1 Some low-voltage power supply FRUs have a voltage selector switch. If it does, the switch needs to be set to the correct voltage for your area. Has the LVPS been changed? Check the switch on the side of the LVPS to verify the correct voltage is set. Go to step 2.
2 Turn the printer off, and remove the rear shield. See “Rear shield removal”. Check the cable at JFUSES1 for proper connection to the controller board, the cable for pinch points, and the cable or connector for any other damage. Is the cable damaged? Replace the fuser cable. Go to step 3.
3 Check the connector JLVPS1 for proper connection to the controller board, the cable for pinch points, and the cable or connector for any other damage. Is the cable damaged? Repair or replace the LVPS cable. Go to step 4.
4 Check the power cable on the left side of the fuser and the thermistor cables and connections on the right side of the fuser. Are the cables or connectors damaged? Repair the cables. If the cables cannot be repaired, replaced the fuser. See “Fuser assembly removal”. Go to step 5.
5 Check the following values at JFUSES1: Are the values approximately correct? Go to step 6. Replace the controller board. See “Controller board removal”.
6 Replace the fuser. See “Fuser assembly removal”. Does the error clear? Problem resolved. Replace the controller board. See “Controller board removal”.
2 Turn the printer off, and remove the rear shield. See “Rear shield removal”. Check the cable at JFUSES1 for proper connection to the controller board, the cable for pinch points, and the cable or connector for any other damage. Is the cable damaged? Replace the fuser cable. Go to step 3.
3 Check the connector JLVPS1 for proper connection to the controller board, the cable for pinch points, and the cable or connector for any other damage. Is the cable damaged? Repair or replace the LVPS cable. Go to step 4.
4 Check the power cable on the left side of the fuser and the thermistor cables and connections on the right side of the fuser. Are the cables or connectors damaged? Repair the cables. If the cables cannot be repaired, replaced the fuser. See “Fuser assembly removal”. Go to step 5.
5 Check the following values at JFUSES1: Are the values approximately correct? Go to step 6. Replace the controller board. See “Controller board removal”.
6 Replace the fuser. See “Fuser assembly removal”. Does the error clear? Problem resolved. Replace the controller board. See “Controller board removal”.