Description: 232.04 Paper fed from the MPF cleared the sensor (input) earlier than expected during a duplex print job. 232.14 Paper fed from tray 1 cleared the sensor (input) earlier than expected during a duplex print job. 232.24 Paper fed from tray 2 cleared the sensor (input) earlier than expected during a duplex print job. 232.34 Paper fed from tray 3 cleared the sensor (input) earlier than expected during a duplex print job. 232.44 Paper fed from tray 4 cleared the sensor (input) earlier than expected during a duplex print job. 232.54 Paper fed from tray 5 cleared the sensor (input) earlier than expected during a duplex print job.
Remedy: Step 1 Check the duplex rollers for damage. Are the rollers free of damage? Go to step 3. Go to step 2. Step 2 Replace the duplex. Does the problem remain? Go to step 3. The problem is solved. Step 3 a Enter the Diagnostics menu, and then navigate to: Printer diagnostics & adjustments > Sensor tests b Find the sensor (Input). Does the sensor status change while toggling the sensor? Go to step 6. Go to step 4. Step 4 Check the sensor cable for proper connection, and then reseat if necessary. Does the problem remain? Go to step 5. The problem is solved. Step 5 Replace the sensor. See “Sensor (input) removal”. Does the problem remain? Go to step 6. The problem is solved. Step 6 Perform a print job. Does the problem remain? Contact the next level of support. The problem is solved.