Code: 905
Description: YK Developer Solenoid Error (YK PSL)
This error indicates the yellow/black developer switching has a problem.
This error indicates the yellow/black developer switching has a problem.
Remedy: 1 Check Connector Check Cable Harness Ensure the black/yellow solenoid connector ECN5 on the IOD2 P.W.B. board is connected. Ensure the cable harness for the solenoid (PSL KY) is not broken. Replace any damaged parts.
2 Developer Solenoid Assembly (PSL KY/ MC) Front Cover Unit Check the voltage at (PSL KY) ON-N. Does the voltage drop below +24V between ECN5-10 and ECN2-6? • If the voltage drops below +24V, replace the DE solenoid assembly. • If this doesn’t fix the problem, replace the front cover unit.
3 IOD2 P.W.B. Board Check the voltage between ECN1-5 and ECN2-8. If the voltage jumps to +24V, replace the IOD2 P.W.B. board.
4 Main Engine (MCTL P.W.B.) Board If the problem still exists, replace the main engine (MCTL P.W.B.) board.
2 Developer Solenoid Assembly (PSL KY/ MC) Front Cover Unit Check the voltage at (PSL KY) ON-N. Does the voltage drop below +24V between ECN5-10 and ECN2-6? • If the voltage drops below +24V, replace the DE solenoid assembly. • If this doesn’t fix the problem, replace the front cover unit.
3 IOD2 P.W.B. Board Check the voltage between ECN1-5 and ECN2-8. If the voltage jumps to +24V, replace the IOD2 P.W.B. board.
4 Main Engine (MCTL P.W.B.) Board If the problem still exists, replace the main engine (MCTL P.W.B.) board.