Code: 906
Description: MC Solenoid Error (MC PSL)
This error indicates the magenta/cyan developer switching has a problem.
This error indicates the magenta/cyan developer switching has a problem.
Remedy: 1 Check Connector Check Cable Harness Ensure the magenta/cyan solenoid connector ECNS on the IOD2 P.W.B. board is connected. Ensure the cable harness for (PSL MC) is not broken. Replace any damaged parts.
2 Developer Solenoid Assembly (PSL KY/MC) Front Cover Unit Check the voltage at (PSL MC) ON-N. Does the voltage drop below +24V between ECN5-7 and ECN2-6? • If the voltage drops below +24V, replace the DE solenoid assembly. • If this does not fix the problem, replace the front cover unit.
3 IOD2 P.W.B. Board Check the voltage between ECN1-6 and ECN2-8. If the voltage jumps to +24V, replace the IOD2 P.W.B. board.
4 Main Engine (MCTL P.W.B.) Boards If the problem still exists, replace the main engine (MCTL P.W.B.) board.
2 Developer Solenoid Assembly (PSL KY/MC) Front Cover Unit Check the voltage at (PSL MC) ON-N. Does the voltage drop below +24V between ECN5-7 and ECN2-6? • If the voltage drops below +24V, replace the DE solenoid assembly. • If this does not fix the problem, replace the front cover unit.
3 IOD2 P.W.B. Board Check the voltage between ECN1-6 and ECN2-8. If the voltage jumps to +24V, replace the IOD2 P.W.B. board.
4 Main Engine (MCTL P.W.B.) Boards If the problem still exists, replace the main engine (MCTL P.W.B.) board.