Code: 916
Description: Ozone Fan (OZFAN) Error
This error indicates a problem with the ozone fan (OZFAN).
This error indicates a problem with the ozone fan (OZFAN).
Remedy: 1 Check Connector Ensure the ozone fan motor connector is properly connected to ECN5 on the IOD2 P.W.B. board. Ensure connectors ECN1 on the IOD2 P.W.B. board and 12CN on the main engine (MCTL P.W.B.) board are properly connected.
2 Ozone Fan Motor (OZFAN) IOD2 P.W.B. Board Check the voltage between ECN3-1 and ECN3-2 on the IOD2 P.W.B. board. If the voltage is +24V, replace the ozone fan (OZFAN). Check the voltage tween ECN1-9 and ECN2-8 on the IOD2 P.W.B. board. If the voltage is less than +24V, replace the IOD2 P.W.B. board.
3 Main Engine (MCTL P.W.B.) Board If the problem still exists, replace the main engine (MCTL P.W.B.) board.
2 Ozone Fan Motor (OZFAN) IOD2 P.W.B. Board Check the voltage between ECN3-1 and ECN3-2 on the IOD2 P.W.B. board. If the voltage is +24V, replace the ozone fan (OZFAN). Check the voltage tween ECN1-9 and ECN2-8 on the IOD2 P.W.B. board. If the voltage is less than +24V, replace the IOD2 P.W.B. board.
3 Main Engine (MCTL P.W.B.) Board If the problem still exists, replace the main engine (MCTL P.W.B.) board.