Code: 917
Description: Fuser Heater Fan (HTFAN) Error
This error indicates a problem with the fuser heater fan (HTFAN).
This error indicates a problem with the fuser heater fan (HTFAN).
Remedy: 1 Check Connector Ensure the fuser heater fan motor connector is properly connected to DCN14 on the IOD1 P.W.B. board. Ensure DCN1 on the IOD1 P.W.B. board and 11CN on the main engine (MCTL P.W.B.) board are connected properly.
2 Fuser Heater Fan (HTFAN) Check the voltage between DCN14-10 and DCN14-11. If the voltage is +24V, replace the fuser heater fan (HTFAN).
3 IOD1 P.W.B. Board Check the voltage between DCN1-35 and DCN1-44. If the voltage is +24V, replace the IOD1 P.W.B. board.
4 Main Engine (MCTL P.W.B.) Board If the problem still exists, replace the main engine (MCTL P.W.B.) board.