Code: 918
Description: Erase LED Error
This error indicates a problem with the erase lamp.
This error indicates a problem with the erase lamp.
Remedy: 1 Check Connector Ensure the erase lamp connector is properly connected to DCN7 on the IOD1 board. Ensure DCN1 on the IOD1 board and 11CN on the main engine (MCTL P.W.B.) board are connected.
2 Erase Lamp (LED P.W.B.) Check for voltage between DCN7-11 and DCN2-25 on the IOD1 board. • If the voltage drops to less than +24V, replace the erase lamp (LED P.W.B.).
3 • IOD1 P.W.B. Board • Main Engine (MCTL P.W.B.) Board Check for voltage between DCN1-27 and DCN1-44 on the IOD2 P.W.B. board. • If the voltage jumps to +24V, replace the IOD1 P.W.B. board. If the problem still exists, replace the main engine (MCTL P.W.B.) board.
2 Erase Lamp (LED P.W.B.) Check for voltage between DCN7-11 and DCN2-25 on the IOD1 board. • If the voltage drops to less than +24V, replace the erase lamp (LED P.W.B.).