Code: 130
Description: Fuser Error Fuser failed to reach standby temperature - hot roll. Hot roll did not reach the correct standby temperature This error displays when the fuser hot roll does not reach the correct standby temperature.
Remedy: 1 Measure the voltage on connector J33-11 on the system board. The voltage measures approximately 0.13 V dc to 0.64 V dc as the hot roll lamp turns off and on. Is the voltage correct? Replace the “Fuser assembly”. Go to step 2 2 Remove the fuser from the printer. Check continuity of the hot roll lamp by measuring between pins 1 and 2 on the AC fuser connector on the fuser assembly. Is there continuity? Go to step 4 Go to step 3 3 Check to make sure that the hot roll lamp is installed correctly. Is the hot roll lamp installed correctly? Go to step 4 Install the lamp correctly. If this does not fix the problem, replace the “Fuser assembly”. 4 Reinstall the fuser assembly. Watch to see if the lamps turn on and off as the lamp heat up. Do the lamps turn on? Go to step 5 Replace the “LVPS assembly”. 5 Turn the printer on and allow it to reach a Ready prompt. Note: The printer may not complete POR and continues to display the error code. Remove the fuser assembly from the printer. Measure the voltage on connector J33-6 on the system board. The voltage should measure approximately +3.3 V dc. Is the voltage correct? Go to step 6 Replace the “System board”. 6 Measure the voltage on the fuser DC control connector on the LVPS. Measure the voltage on pin 6 of the connector. Does the voltage measure approximately +3.3 V dc? Replace the “Fuser assembly”. Replace the “LVPS assembly”.