Code: 196
Description: Service Thermal System. The printer has detected an error in the printhead thermal drift compensation system.
Remedy: Drift Sensors This check is used to display the status of the thermal system used to compensate for printhead drift. The following screen is displayed when the test is selected: Values: If Com=Err, replace the system board. See “System board”. If a number, C, Y, or K=OP, or SH, check the following: 1. Check the cable of the appropriate thermistor (cyan, magenta, yellow, or black) to make sure it is installed correctly to the system board and to the thermistor board. If correct, go to step 2. 2. Check the continuity of the appropriate cable. Replace the cable if there is no continuity. If continuity is correct, go to step 3. 3. Replace the appropriate thermistor assembly. If this does not fix the problem, replace the system board. To exit the test, press Return or Stop.