Mã lỗi 122.04 — Lexmark C772n

Code: 122.04

Description: Fuser cold.
Remedy: 1 Measure the voltage on connector J17-11 on the system board. The voltage should measure approximately +0.13 V dc to +0.64 V dc as the hot roll lamp turns off and on. Is the voltage correct? Go to step 2 Replace the system board. See “System board removal”. 2 Remove the fuser from the printer. Check continuity of the hot roll lamp by measuring between pins 1 and 2 on the AC fuser connector on the fuser assembly. Is there continuity? Go to step 4 Go to step 3 3 Check to make sure the hot roll lamp is installed correctly. Is the hot roll lamp installed correctly? Go to step 4 Install the lamp correctly. If this does not fix the problem, replace the fuser assembly. See “Fuser assembly removal”. 4 Reinstall the fuser assembly. Watch to see if the lamps turn on and off as the lamp heats up. Do the lamps turn on? Go to step 5 Replace the fuser assembly. See “Fuser assembly removal”. 5 Turn the printer on, and allow it to reach a Ready prompt. Note: The printer may not complete POR and may continue to display the error code. Remove the fuser from the printer. Measure the voltage on connector J17-6 on the system board. The voltage should measure approximately 3.3 V dc. Is the voltage correct? Go to step 6 Replace the system board. See “System board removal”. 6 Measure the voltage on the fuser DC control connector on the LVPS. Measure the voltage on pin 6 of the connect. Does the voltage measure approximately +3.3 V dc? Replace the fuser assembly. See “Fuser assembly removal”. Replace the LVPS assembly. See “LVPS assembly removal”.

← Xem tất cả mã lỗi Lexmark C772n

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie