Mã lỗi 122.03 — Lexmark C782n

Code: 122.03

Description: Fuser open thermistor. Hot roll thermistor circuit is open If error code 122.03 displays, the printer detects a problem in the fuser hot roll, fuser hot roll thermistor, system board, or LVPS fuser control circuits.
Remedy: 1 Turn the printer on, and allow it to reach the Ready prompt. Note: The printer may not complete POR and post a 122.03 Error message. Measure the voltage on connector J17-6 on the system board. The voltage should measure approximately +3.3 V dc. Is the voltage correct? Go to step 2 Replace the system board. See “System board removal”. 2 Measure the voltage on the fuser DC control connector on the LVPS. Measure the voltage on pin 6 of the connector. Does the voltage measure approximately +3.3 V dc? Replace the fuser assembly. See “Fuser assembly removal”. Replace the LVPS assembly. See “LVPS assembly removal”.