Code: 122.05, 122.06
Description: 122.05 Fuser does not raise temperature quickly enough or raises temperature too quickly. 122.06 Fuser Error Fuser failed to raise temperature quickly enough or raises temperature too quickly
Remedy: 1 Measure the voltage on connector J17-11 on the system board. The voltage measures approximately 0.13 V dc to 0.64 V dc as the hot roll lamp turns off and on. Is the voltage correct? Replace the fuser assembly. See “Fuser assembly removal”. Go to step 2 2 Remove the fuser from the printer. Check continuity of the hot roll lamp by measuring between pins 1 and 2 on the AC fuser connector on the fuser assembly. Is there continuity? Go to step 4 Go to step 3 3 Check to make sure that the hot roll lamp is installed correctly. Is the hot roll lamp installed correctly? Go to step 4 Install the lamp correctly. If this does not fix the problem, replace the fuser assembly. See “Fuser assembly removal”. 4 Reinstall the fuser assembly. Watch to see if the lamps turn on and off as they heat up. Do the lamps turn on? Go to step 5 Replace the LVPS assembly. See “LVPS assembly removal”. 5 Turn the printer on, and allow it to reach a Ready prompt. Note: The printer may not complete POR and continues to display the error code. Remove the fuser assembly from the printer. Measure the voltage on connector J17-6 on the system board. The voltage should measure approximately +3.3 V dc. Is the voltage correct? Go to step 6 Replace the system board. See “System board removal”. 6 Measure the voltage on the fuser DC control connector on the LVPS. Measure the voltage on pin 6 of the connector. Does the voltage measure approximately +3.3 V dc? Replace the fuser assembly. See “Fuser assembly removal”. Replace the LVPS assembly. See “LVPS assembly removal”.