Mã lỗi 201.01, 201.51 — Lexmark C792de

Code: 201.01, 201.51

Description: 201.01 Bubble sensor active when printer powers up or a cover is closed. Possible causes: • Paper jam leaving paper over the sensor • Damaged bubble sensor • Damaged fuser autoconnect • Faulty fuser DC cable connection • Faulty fuser • Faulty system board 201.51 Bubble sensor active when printer powers up or a cover is closed. (Fuser past life)
Remedy: 1 Open the left access door, and check the fuser bubble sensor flag. Is the bubble sensor flag damaged? Replace the damaged sensor. See “Sensor (D1, D2, and fuser bubble) removal”. Go to step 2. 2 Open the system board shield. Check the cable in connector JDP1 for proper connection to the system card. Is the cable properly connected? Go step 3. Reseat the cable. 3 Check the cable for damage. Is the cable damaged? Replace the duplexer cable. To access the cable, see “LVPS exit duct removal” and “Left cover removal”. Go step 4. 4 Remove the duplex cable cover. Check the cable for proper connection. Is the cable connected correctly? Go to step 5. Reseat the cable. 5 Check the cable for damage. Is the cable connected correctly? Replace the duplexer cable. To access the cable, see “LVPS exit duct removal” and “Left cover removal”. Go to step 6. 6 Replace the duplex assembly. See “Duplex assembly removal”. Is the problem fixed? Problem solved. Replace the system board. See “System board removal”.

← Xem tất cả mã lỗi Lexmark C792de

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie