Description: Exit sensor is made early. Possible causes: • Incorrect paper settings • Defective exit sensor 202.52 Exit sensor is made early. (Fuser past life)
Remedy: 1 Replace the fuser. See “Fuser assembly removal”. Does the error clear? Problem solved. Go to step 2. 2 Open the system board shield. Check the cable in connector JFSR1 (D) for proper connection to the system board. Is the cable properly connected? Go to step 3. Reseat the cable. 3 Check the cable for damage. Is the cable damaged? Replace the Fuser and system card LVPS cable. See “Fuser system card and LVPS cable removal”. Go to step 4. 4 Check the cable (F) on the LVPS for proper connection. Is the cable properly connected? Go to step 5. Reseat the cable. 5 Check the cable on the LVPS for damage. Is the cable damaged? Replace the Fuser and system card LVPS cable. See “Fuser system card and LVPS cable removal”. Go to step 6. 6 Open the left access door, remove the two screws (A), and pull out the fuser autoconnect enough to check the cable for proper connection. Is the cable properly connected? Go to step 7. Reseat the cable. 7 Check the cable for damage. Is the cable damaged? Replace the Fuser and system card LVPS cable. See “Fuser system card and LVPS cable removal”. Reseat the cable.