Description: Multipurpose feeder motor stalled. Possible causes: • Tray 1 motor failure • Cabling failure • MPF gear assembly failure • System board failure
Remedy: 1 Open the left access door. Does the MPF wheels turn freely? Go to step 3. Go to step 2. 2 Remove the LVPS fan shield. See “LVPS exit duct removal”. Are the gears (A) damaged? Replace the MPF pick parts. See “MPF pick parts packet, including”. Replace the MPF paper pick assembly. See “MPF paper pick assembly removal (including the MPF ratchet collar and MPF drive pulley)”. 3 Turn the printer off, and open the system board shield. Check the cable in connector JTRAY1 for proper connection to the system card. Is the cable connected correctly? Go to step 4. Reseat the cable. 4 Check the cable in connector JTRAY1 for damage. Is the cable damaged? Replace the Tray 1 machine side cable. See “Autocomp W2W cable”. Go to step 5. 5 Remove the input tray. Is the input tray cable connected correctly? Go to step 6. Reseat the cable. 6 Remove the LVPS. See “Low-voltage power supply (LVPS) removal”. Is the MPF drive belt (B) broken? Replace the MPF drive belt. See “MPF drive assembly removal”. Go to step 7. 7 Is the MPF drive assembly damaged? Replace the MPF drive assembly. See “MPF drive assembly removal”. Go to step 8. 8 Replace the Input tray feed assembly. Does the error reoccur? Replace the System Board. See “System board removal”. Problem solved.