Remedy: • Insert the waste toner box. • Check the cable in connector JBUMP1on the system board for defects and proper connection. If the cable wiring or the cable connection is defective, replace the bump multipurpose feeder/duplex motor assembly. See “Duplex assembly removal”. If the cable in JBUMP1 connector is damaged on the system board, replace the system board. See “System board removal”. • Check the aligner shaft and the mechanical system for binds. • Replace the bump multipurpose feeder/duplex motor assembly. See “Duplex assembly removal”. • If the problem persists, replace the system board. See “System board removal”.