Description: Finisher Tractor Motor Error
Remedy: 1 Are there obstructions or foreign objects in the accumulator or face down paper path? Remove the objects or obstructions. Go to step 2.
2 Are the connectors CN3 at the tractor motor and PJ4 on the finisher control board securely connected? Go to step 3. Securely connect the connectors.
3 Make sure the finisher set switch is activated. Measure +24 V dc between pin 1 of tractor motor connector CN3 and frame ground. Is +24 V dc (±10%)? Go to step 4. Go to step 5.
4 Replace the tractor motor assembly. Did this resolve the problem? Problem solved. Replace the finisher control board.
5 Disconnect CN3 and PJ4 on the finisher control board and perform a continuity check on all positions. Is there continuity on all positions? Go to step 6. Replace the cable.
6 Check for +24 V dc between pins 1 and 2 of PJ3 on the finisher control board. Is +24 V dc present? Replace the finisher control board. Replace the power supply.
2 Are the connectors CN3 at the tractor motor and PJ4 on the finisher control board securely connected? Go to step 3. Securely connect the connectors.
3 Make sure the finisher set switch is activated. Measure +24 V dc between pin 1 of tractor motor connector CN3 and frame ground. Is +24 V dc (±10%)? Go to step 4. Go to step 5.
4 Replace the tractor motor assembly. Did this resolve the problem? Problem solved. Replace the finisher control board.
5 Disconnect CN3 and PJ4 on the finisher control board and perform a continuity check on all positions. Is there continuity on all positions? Go to step 6. Replace the cable.
6 Check for +24 V dc between pins 1 and 2 of PJ3 on the finisher control board. Is +24 V dc present? Replace the finisher control board. Replace the power supply.