Code: 996
Description: Finisher Jogging Motor Error
Remedy: 1 Are there foreign objects or obstructions in the jogging assembly? Clear the objects or obstruction. Go to step 2.
2 Are the jogging motor connectors CN2 on the finisher control board securely connected? Go to step 3. Securely connect the connectors.
3 Make sure the finisher set switch is activated. Measure for +24 V dc (±10%) between pin 1 on CN2 and frame ground. Is +24 V dc present? Go to step 4. Go to step 5.
4 Replace the jogging motor assembly. Did this resolve the problem? Problem solved. Replace the finisher control board.
5 Disconnect CN2 and PJ5. Perform a continuity check on the cable for all positions. Is there continuity? Go to step 6. Replace the cable.
6 Check for +24 V dc (±10%) between pins 1 and 2 of PJ3 on the finisher control board. Is +24 V dc present? Replace the finisher control board. Replace the power supply.
2 Are the jogging motor connectors CN2 on the finisher control board securely connected? Go to step 3. Securely connect the connectors.
3 Make sure the finisher set switch is activated. Measure for +24 V dc (±10%) between pin 1 on CN2 and frame ground. Is +24 V dc present? Go to step 4. Go to step 5.
4 Replace the jogging motor assembly. Did this resolve the problem? Problem solved. Replace the finisher control board.
5 Disconnect CN2 and PJ5. Perform a continuity check on the cable for all positions. Is there continuity? Go to step 6. Replace the cable.
6 Check for +24 V dc (±10%) between pins 1 and 2 of PJ3 on the finisher control board. Is +24 V dc present? Replace the finisher control board. Replace the power supply.