Code: 923
Description: Upper Fuser Thermistor Open Error
Remedy: 1 Is connector CN19 on the printer controller board connected properly? Disconnect CN19 and turn the printer on. Go to step 2. Plug the connector in securely. 2 Is error 923 displayed? Power off, and reconnect CN19. Go to step 3. Replace the printer controller board. 3 Power the printer off and short-circuit pins (1 and 2) and (3 and 4) of CN19 and power on. Is error 923 displayed? Replace the fuser. Replace the printer controller board.