Description: Service fuser error Front thermistor disconnection error
Remedy: 1 Check the fuser unit assembly for a media jam. Is there a media jam in the fuser unit assembly? Remove the media. Go to step 2. 2 Check the fuser unit assembly for proper installation. Is the fuser unit assembly installed properly? Go to step 3. Install the fuser unit assembly properly. 3 Check the fuser unit assembly for proper connection. Is the above component properly connected. Go to step 4. Repair the connection. 4 Perform a POR. Does the error occur when the power is turned off/on? Replace the fuser unit assembly. Go to “Fuser unit assembly removal”. Problem solved.