Code: 150, 160
Description: 150.80 The motor (duplex/MPF) did not turn on. 160.80 The motor (duplex/MPF) did not turn on. 150.81 The motor (duplex/MPF) did not turn off. 160.81 The motor (duplex/MPF) did not turn off. 150.82 The motor (duplex/MPF) speed did not ramp up to the required level. 160.82 The motor (duplex/MPF) speed did not ramp up to the required level. 150.83 The motor (duplex/MPF) stalled. 160.83 The motor (duplex/MPF) stalled. 150.84 The motor (duplex/MPF) ran too slow. 160.84 The motor (duplex/MPF) ran too slow. 150.85 The motor (duplex/MPF) ran too fast. 150.86 The motor (duplex/MPF) did not run at the correct timing. 160.86 The motor (duplex/MPF) did not run at the correct timing.
Remedy: Step 1 Reset the printer. Does the problem remain? Go to step 2. The problem is solved. Step 2 a Enter the Diagnostics menu, and then navigate to: Printer diagnostics & adjustments > Motor tests > Duplex/MPF b Touch Start. Does the motor run? Go to step 3. Go to step 5. Step 3 Open the front door, and then manually turn the duplex/MPF drive gears. Is there binding in the gears? Go to step 4. Go to step 5. Step 4 Replace the motor. See “Motor (duplex/MPF) removal”. Does the problem remain? Go to step 5. The problem is solved. Step 5 Check the motor cable for proper connection and damage, and replace if necessary. Does the problem remain? Go to step 6. The problem is solved. Step 6 Replace the controller board. See “Controller board removal”. Does the problem remain? Contact the next level of support. The problem is solved.