Description: 100.32 The duplex path 1 sensor cable is unplugged. 100.33 The output bin full sensor cable is unplugged.
Remedy: Step 1 Check the following sensors for proper connection, and reseat if necessary: • Sensor (output) • Sensor (bin full) Does the problem remain? Go to step 2. The problem is solved. Step 2 Check the sensor cables for proper connection on the sensors and on the JDSNS1 connector on the controller board. Are the cables properly connected at both ends? Go to step 4. Go to step 3. Step 3 Reconnect the cables. Does the problem remain? Go to step 4. The problem is solved.