Code: 85
Description: 85.01 The black imaging unit is nearly low. The photoconductor threshold has been reached. 85.09 The black imaging unit is nearly low. The user.selected EWS set point has been reached. 85.11 The black imaging unit is low. The photoconductor threshold has been reached. 85.19 The black imaging unit is low. The user.selected EWS set point has been reached. 85.21 The black imaging unit is very low. The photoconductor threshold has been reached. 85.29 The black imaging unit is very low. The user.selected EWS set point has been reached. 85.31 Replace the black imaging unit. The black imaging unit has exceeded its recommended life span. The photoconductor threshold for gEnd of Lifeh has been reached. The black developer may continue to function beyond end of life. 85.39 Replace black imaging unit. The black imaging unit has exceeded its recommended life span. The user.selected EWS set point has been reached. The black developer may continue to function beyond end of life. 85.41 Replace black imaging unit to resume printing. The photoconductor threshold for gAbsolute End of Lifeh has been reached.
Remedy: Step 1 a Make sure that the cartridge or photoconductor is installed. b Check if the cartridge or photoconductor is supported, and replace if necessary. Does the problem remain? Go to step 2. The problem is solved. Step 2 a Make sure that the cartridge or photoconductor is properly installed. b Make sure that the cartridge or photoconductor cables are properly connected. Does the problem remain? Go to step 3. The problem is solved. Step 3 Check the cartridge or photoconductor contacts for damage, and replace if necessary. Does the problem remain? Go to step 4. The problem is solved. Step 4 Check the controller board pins for damage, and replace if necessary. See “Controller board removal”. Does the problem remain? Contact the next level of support. The problem is solved.