Description: The flatbed cover is open before starting ADF job.
Remedy: Step 1 Check if the ADF is completely closed and resting on the flatbed. Is the ADF completely closed and resting on the flatbed? Go to step 3. Go to step 2. Step 2 Close the ADF completely until it rests on the flatbed. Does the problem remain? Go to step 3. The problem is solved. Step 3 Reset the printer, and then perform an ADF scan job. Does the problem remain? Go to step 4. The problem is solved. Step 4 a Enter the Diagnostics menu, and then navigate to: Scanner diagnostics > Sensor tests b Find the sensor (ADF closed). Does the sensor status change while toggling the sensor? Go to step 7. Go to step 5. Step 5 Check the actuator for misalignment and damage. Is the actuator misaligned or damaged? Go to step 6. Go to step 7. Step 6 Replace the ADF. See “ADF removal”. Does the problem remain? Go to step 7. The problem is solved. Step 7 Perform an ADF scan job. Does the problem remain? Contact the next level of support. The problem is solved.