Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 920.08 — Lexmark CS736

Code: 920.08

Description: POST Error
Exit sensor not connected.
Remedy: 1 Verify the paper is loaded properly in the paper tray or manual feed slot. Is the paper properly loaded? Go to step 2. Load paper correctly.
2 Turn the printer off, and remove the fuser. See “Fuser removal”. POR the printer. Did the error clear? Problem resolved. Remove the new fuser, and go to step 3.
3 Remove the rear frame cover. See “Rear frame cover removal”. Check the fuser DC cable in the connector JFUSER1 for proper connection to the system board, for pinch points, and for any other damage to the cable or the connector. Is the cable damaged? Replace the fuser DC cable. See “Fuser DC cable removal”. Go to step 5.
4 Place a voltmeter between the fuser DC autoconnect pin 8 and ground (pin 6). Does the meter rear +5 V dc? Go to step 6. Go to step 5.
5 Place a voltmeter between the connector JFUSER1 pin 8 and ground (pin 6) on the system board. Does the meter read +5 V dc? Go to step 6. Replace the fuser DC cable. See “Fuser DC cable removal”.
6 1. Replace the fuser. 2. Bring the printer up in Diagnostics Menu (turn off the printer, press and hold and . and turn on the printer). 3. Select SENSOR TESTS, and press Select( ). 4. Select Dynamic Sensors, and press Select( ). 5. Select Fuser Exit, and press Select( ). 6. Open the front door, and then the top access cover. 7. Activate the fuser exit sensor. Did the fuser exit sensor change from Open to Closed? Problem resolved. Replace the system board. See “System board removal”.