Code: 9F
Description: Paper empty
Causes: 1 Dirt on PE sensor. 2 Harness connection failure of PE EG sensor PCB ASSY. 3 PE actuator catching on some position. 4 PE sensor failure. 5 HVPS PCB unit failure. 6 Main PCB failure
Remedy: 1 Dirt on PE sensor Clean the PE sensor. 2 Harness connection failure of PE EG sensor PCB ASSY. Check the harness connection of the PE EG sensor PCB ASSY and reconnect it. 3 PE actuator catching on some position Correct catching of the PE actuator. 4 PE sensor failure Check the sensor performance following the procedure described in “Maintenance mode 32”. If any problem occurs, replace the PE PG sensor PCB ASSY. 5 HVPS PCB unit failure Replace the HVPS PCB unit. 6 Main PCB failure Replace the main PCB ASSY.