Description: 126.01 LVPS line voltage error was detected. 126.02 LVPS line voltage error was detected. 126.06 LVPS 25V line error was detected. 126.07 LVPS 5V rail was down during POR. 126.10 No line frequency was detected. 126.11 Line frequency has gone outside the op127.02 HVPS secondary power supply was not detected.erating range. 127.01 HVPS primary power supply was not detected.
Remedy: Step 1 Reset the printer. Does the problem remain? Go to step 2. The problem is solved. Step 2 Check the HVPS cable on the JHVPS connector on the controller board for proper connection. Is the cable properly connected at both ends? Go to step 4. Go to step 3. Step 3 Reconnect the cable. Does the problem remain? Go to step 4. The problem is solved. Step 4 Check the cable for damage, and replace if necessary. Does the problem remain? Go to step 5. The problem is solved. Step 5 Replace the HVPS. See “HVPS removal”. Does the problem remain? Go to step 6. The problem is solved. Step 6 Replace the controller board. See “Controller board removal”. Does the problem remain? Contact the next level of support. The problem is solved.