Description: 145.80 The motor (BOR) did not turn on. 145.81 The motor (BOR) did not turn off. 145.82 The motor (BOR) speed did not ramp up to the required level. 145.83 The motor (BOR) stalled. 145.84 The motor (BOR) ran too slow. 145.85 The motor (BOR) ran too fast. 145.86 The motor (BOR) did not run at the correct timing.
Remedy: Step 1 Reset the printer. Does the problem remain? Go to step 2. The problem is solved. Step 2 a Remove the transfer module. See “Transfer module removal”. b Enter the Diagnostics menu, and then navigate to: Printer diagnostics & adjustments > Motor tests > Black only retract c Touch Start. Does the motor run? Go to step 3. Go to step 5. Step 3 Manually turn the BOR gear on the transfer module. Does the gear freely turn? Contact the next level of support. Go to step 4. Step 4 Replace the transfer module. See “Transfer module removal”. Does the problem remain? Go to step 9. The problem is solved. Step 5 Check the cable on the motor and on the JBOR1 connector on the controller board for proper connection. Is the cable properly connected at both ends? Go to step 7. Go to step 6.