Code: 653
Description: 653.80 The motor (ISO) did not turn on. 653.81 The motor (ISO) did not turn off. 653.82 The motor (ISO) speed did not ramp up to the required level. 653.83 The motor (ISO) stalled. 653.84 The motor (ISO) ran too slow. 653.85 The motor (ISO) ran too fast. 653.86 The motor (ISO) did not run at the correct timing.
Remedy: Step 1 Reset the printer. Does the problem remain? Go to step 2. The problem is solved. Step 2 a Enter the Diagnostics menu, and then navigate to: Printer diagnostics & adjustments > Motor tests > Isolation b Touch Start. Does the motor run? Go to step 3. Go to step 5. Step 3 Manually turn the isolation unit input rollers. Is there binding or uneven movement when turning the rollers? Go to step 4. Go to step 5. Step 4 Replace the isolation unit. See “Isolation unit removal”. Does the problem remain? Go to step 5. The problem is solved. Step 5 Check the cable on the motor and on the JMTR1 connector on the controller board for proper connection. Is the cable properly connected at both ends? Go to step 7. Go to step 6. Step 6 Reconnect the cable. Does the problem remain? Go to step 7. The problem is solved. Step 7 Check the cable for damage, and replace if necessary. Does the problem remain? Go to step 8. The problem is solved. Step 8 Replace the controller board. See “Controller board removal”. Does the problem remain? Contact the next level of support. The problem is solved.