Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 213.91 — Lexmark CX820de

Code: 213.91

Description: Paper remains detected at the sensor (deskew roller exit) after the printer is turned on.
Remedy: Step 1 Check the paper path for paper jams and fragments. Is the paper path free of jams and fragments? Go to step 3. Go to step 2. Step 2 Remove the paper jams and fragments. Does the problem remain? Go to step 3. The problem is solved. Step 3 a Enter the Diagnostics menu, and then navigate to: Printer diagnostics & adjustments > Sensor tests b Find the sensor (Deskew roller exit). Does the sensor status change while toggling the sensor? Go to step 8. Go to step 4. Step 4 Check the sensor cable for proper connection, and then reseat if necessary. Does the problem remain? Go to step 5. The problem is solved. Step 5 Check the deskew roller for contamination and damage. Is the roller free of contamination and damage? Go to step 7. Go to step 6. Step 6 Clean or replace the deskew roller. Does the problem remain? Go to step 7. The problem is solved. Step 7 Replace the sensor (deskew roller exit). Does the problem remain? Go to step 8. The problem is solved. Step 8 Perform a print job. Does the problem remain? Contact the next level of support. The problem is solved.