Mã lỗi A1 — Brother MFC8890DW

Code: A1

Description: Front cover opened
Causes: 1 Harness connection failure of front cover sensor ASSY. 2 Part pressing the front cover sensor ASSY is broken, which is provided at the left side of the front cover inside. 3 Front cover sensor failure. 4 Relay front PCB failure. 5 Main PCB failure
Remedy: 1 Harness connection failure of front cover sensor ASSY Check the harness connection of the front cover sensor ASSY and reconnect it. 2 Part pressing the front cover sensor ASSY is broken, which is provided at the left side of the front cover inside. Replace the front door main or front door unit ASSY. 3 Front cover sensor failure Check the sensor performance following the procedure described in “Maintenance mode 32”. If any problem occurs, replace the front cover sensor ASSY. 4 Relay front PCB failure Replace the relay front PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.