Mã lỗi 383.60...383.61 — Lexmark CX860

Code: 383.60...383.61

Description: 383.60 The motor (staple unit carriage) did not turn on. 383.61 The motor (staple unit carriage) did not turn off.
Remedy: Step 1 a Check the MSHPF for proper installation, and then check its paper path. See “Procedure before starting the MSHPF service checks”. b Enter the Diagnostics menu, select Output bin quick feed > select bin, and then touch Single or Continuous. Does the problem remain? Go to step 2. The problem is solved. Step 2 Check the MSHPF staple cartridge door for misalignment and damage. Note: When closing the door, its actuator should properly engage with the door sensor and switch. Is the door properly installed and free of damage? Go to step 4. Go to step 3. Step 3 Reinstall or replace the door. See “MSHPF staple cartridge door removal”. Does the problem remain? Go to step 4. The problem is solved. Step 4 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Sensor tests > Finisher b Find the sensor (Cartridge door interlock switch). Does the sensor status change while toggling the switch? Go to step 10. Go to step 5. Step 5 Reseat the switch cable, and then check the switch for misalignment and damage. Is the switch properly installed and free of damage? Go to step 7. Go to step 6. Step 6 Reinstall or replace the switch. See “Switch (MSHPF cartridge door interlock) removal”. Does the problem remain? Go to step 7. The problem is solved. Step 7 Check the door interlock cable for proper connection. • Reseat the cable. • Make sure that the cable is properly routed. Does the problem remain? Go to step 8. The problem is solved. Step 8 Check the cable for cuts and damage. Is the cable free of damage? Go to step 10. Go to step 9. Step 9 Replace the cable. Does the problem remain? Go to step 10. The problem is solved. Step 10 a Remove the staple cartridge holder, and then check for staple and paper fragments. b Check the cartridge holder for damage. Is the cartridge holder free of fragments and damage? Go to step 12. Go to step 11. Step 11 Remove the fragments, and then reinstall or replace the cartridge holder. Note: Remove the remaining partial slabs of staples so that only the full slabs remain. Does the problem remain? Go to step 12. The problem is solved. Step 12 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Sensor tests > Finisher b Find the sensor (Cartridge loading position). Does the sensor status change while toggling the sensor? Go to step 15. Go to step 13. Step 13 Reseat the sensor cable, and then check the sensor for misalignment and damage. Is the sensor properly installed and free of damage? Go to step 15. Go to step 14. Step 14 Reinstall or replace the sensor. See “Sensor (cartridge loading position) removal”. Does the problem remain? Go to step 15. The problem is solved. Step 15 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Sensor tests > Finisher b Find the sensor (Staple unit position). Does the sensor status change while toggling the sensor? Go to step 18. Go to step 16. Step 16 Reseat the sensor cable, and then check the sensor for misalignment and damage. Is the sensor properly installed and free of damage? Go to step 18. Go to step 17. Step 17 Reinstall or replace the sensor. See “Sensor (MSHPF staple unit position) removal”. Does the problem remain? Go to step 18. The problem is solved. Step 18 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Sensor tests > Finisher b Find the sensor (Staple unit paper present). Does the sensor status change while toggling the sensor? Go to step 21. Go to step 19. Step 19 Reseat the sensor cable, and then check the sensor for misalignment and damage. Is the sensor properly installed and free of damage? Go to step 21. Go to step 20. Step 20 Reinstall or replace the sensor. See “Sensor (MSHPF staple unit paper present) removal”. Does the problem remain? Go to step 21. The problem is solved. Step 21 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Motor tests > Finisher b Perform all the motor tests involving the staple unit position. Does the motor run? Go to step 24. Go to step 22. Step 22 Reseat the motor cable, and then check the motor for misalignment and damage. Is the motor properly installed and free of damage? Go to step 24. Go to step 23. Step 23 Reinstall or replace the motor. See “Motor (staple unit carriage) removal”7. Does the problem remain? Go to step 24. The problem is solved. Step 24 Check the staple carriage belt for misalignment and damage. Note: Make sure that there are no other parts interfering with the movement of the belt. Is the belt properly installed and free of damage? Go to step 26. Go to step 25. Step 25 Reinstall or replace the belt. See “Staple unit carriage belt removal”7. Does the problem remain? Go to step 26. The problem is solved. Step 26 Check the staple unit carriage gear for misalignment and damage. Is the gear properly installed and free of damage? Go to step 28. Go to step 27. Step 27 Reinstall or replace the gear. Does the problem remain? Go to step 28. The problem is solved. Step 28 Check the carriage rail for misalignment and damage. Is the carriage rail properly installed and free of damage? Go to step 30. Go to step 29. Step 29 Reinstall or replace the carriage rail. Does the problem remain? Go to step 30. The problem is solved. Step 30 Check the staple unit for proper installation. • Check the staple unit for misalignment. • Reseat the staple unit extension cable. Is the staple unit properly installed? Go to step 32. Go to step 31. Step 31 Reinstall or replace the staple unit. See “MSHPF staple unit removal”. Does the problem remain? Go to step 32. The problem is solved. Step 32 Check the MSHPF staple unit carriage and its cables for damage. Is the carriage free of damage? Go to step 33. Go to step 34. Step 33 Check the MSHPF staple unit carriage for proper installation. • Check the staple unit carriage for misalignment. • Reseat the staple unit cable. Is the staple unit carriage properly installed? Go to step 35. Go to step 34. Step 34 Replace the staple unit carriage. See “MSHPF staple unit carriage removal”. Does the problem remain? Go to step 35. The problem is solved. Step 35 a Reseat the staple unit cable and staple unit extension cable. b Make sure that the cables are properly routed. Does the problem remain? Go to step 36. The problem is solved. Step 36 Check the carriage cables for cuts and damage. Are the cables free of damage? Go to step 38. Go to step 37. Step 37 Replace the cable. See “Staple unit extension cable removal” and “Staple unit cable removal”9. Does the problem remain? Go to step 38. The problem is solved. Step 38 Check the compiler interface board cables. • Reseat all connectors on the interface board. • Make sure that the cables are properly routed. Does the problem remain? Go to step 39. The problem is solved. Step 39 Replace the interface board. See “Compiler interface board removal”2. Does the problem remain? Go to step 40. The problem is solved. Step 40 Check the interface board cables for cuts and damage. Are the cables free of damage? Go to step 42. Go to step 41. Step 41 Replace the cable. Does the problem remain? Go to step 42. The problem is solved. Step 42 a Reseat all connectors on the MSHPF controller board. b Make sure that the cables are properly routed, and then reset the printer. Does the problem remain? Go to step 43. The problem is solved. Step 43 Replace the MSHPF controller board. See “MSHPF controller board removal”. Does the problem remain? Contact the next level of support. The problem is solved.

← Xem tất cả mã lỗi Lexmark CX860

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie