Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 401.11...401.15 — Lexmark CX860de

Code: 401.11...401.15

Description: 401.11 Paper remains detected at the sensor 2 (HPT transport) after the printer is turned on. 401.13 Paper never arrived at the sensor 2 (HPT transport). 401.15 Paper never cleared the sensor 2 (HPT transport).
Remedy: Step 1 a Check the HPT and multiposition staple, hole punch finisher for proper installation. b Open door K and clear paper jams, fragments, and obstructions along the paper path. c Enter the Diagnostics menu, and then touch Output bin quick feed. d Select a bin and test type, and then start the test. Does the problem remain? Go to step 2. The problem is solved. Step 2 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Sensor tests > Horizontal paper transport b Find the sensor (HPU entrance). Does the sensor status change while toggling the sensor? Go to step 5. Go to step 3. Step 3 Reseat the sensor cable, and then check the sensor and actuator for misalignment and damage. Is the sensor properly installed and free of damage? Go to step 5. Go to step 4. Step 4 Reinstall or replace the sensor. See “Sensor (HPU entrance) removal”. Does the problem remain? Go to step 5. The problem is solved. Step 5 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Motor tests > Finisher b Find the motor (HPT transport and fan), and then touch Start. Does the motor run? Go to step 8. Go to step 6. Step 6 Reseat the motor cable, and then check the motor for misalignment and damage. Is the motor properly installed and free of damage? Go to step 8. Go to step 7. Step 7 Reinstall or replace the motor. See “Motor (HPT transport) removal”. Does the problem remain? Go to step 8. The problem is solved. Step 8 Check the HPT transport drive belt for misalignment and damage. Is the belt properly installed and free of damage? Go to step 10. Go to step 9. Step 9 Reinstall or replace the belt. See “HPT transport drive belt removal”. Does the problem remain? Go to step 10. The problem is solved. Step 10 Check the HPT transport drive gear for wear and damage. Is the gear properly installed and free of damage? Go to step 12. Go to step 11. Step 11 Replace the gear. See “HPT transport gears removal”. Does the problem remain? Go to step 12. The problem is solved. Step 12 Check the HPT transport gear for wear and damage. Is the gear properly installed and free of damage? Go to step 14. Go to step 13. Step 13 Replace the gear. See “HPT transport gears removal”. Does the problem remain? Go to step 14. The problem is solved. Step 14 Check the HPT transport belts for misalignment and damage. Are the belts properly installed and free of damage? Go to step 16. Go to step 15. Step 15 Reinstall or replace the belts. See “HPT transport belts removal”. Does the problem remain? Go to step 16. The problem is solved. Step 16 Check the HPT front transport belt gear for wear and damage. Is the gear properly installed and free of damage? Go to step 18. Go to step 17. Step 17 Replace the gear. See “HPT front transport belt gear removal”. Does the problem remain? Go to step 18. The problem is solved. Step 18 a Manually turn knob K1 and the hole punch unit gears. b Check if the punch rotates with the knob and gears. Does the punch rotate with knob K1 and the gears? Go to step 20. Go to step 19. Step 19 Replace the hole punch unit. Does the problem remain? Go to step 20. The problem is solved. Step 20 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Sensor tests > Horizontal paper transport b Find the sensor (HPU). Does the sensor status change while toggling the sensor? Go to step 23. Go to step 21. Step 21 Reseat the sensor cable, and then check the sensor and actuator for misalignment and damage. Is the sensor properly installed and free of damage? Go to step 23. Go to step 22. Step 22 Reinstall or replace the sensor. See “Sensor (hole punch unit) removal”. Does the problem remain? Go to step 23. The problem is solved. Step 23 a Enter the Diagnostics menu, and then navigate to: Output device diagnostics > Motor tests > Finisher b Find the motor (HPU), and then touch Start. Does the motor run? Go to step 26. Go to step 24. Step 24 Reseat the motor cable, and then check the motor for misalignment and damage. Is the motor properly installed and free of damage? Go to step 26. Go to step 25. Step 25 Reinstall or replace the motor. See “Motor (hole punch unit) removal”. Does the problem remain? Go to step 26. The problem is solved. Step 26 Check the hole punch unit gears for misalignment and damage. Are the gears properly installed and free of damage? Go to step 28. Go to step 27. Step 27 Reinstall or replace the gears. See “Hole punch unit gears removal”. Does the problem remain? Go to step 28. The problem is solved. Step 28 Check the HPT alignment rollers for misalignment, wear, damage, and contamination. Are the rollers properly installed and free of wear, damage, and contamination? Go to step 30. Go to step 29. Step 29 Reinstall or replace the rollers. See “HPT alignment rollers removal”. Does the problem remain? Go to step 30. The problem is solved. Step 30 Check the HPT transport idler roller for misalignment and damage. Is the roller properly installed and free of damage? Go to step 32. Go to step 31. Step 31 Reinstall or replace the roller. See “HPT transport idler roller removal ”. Does the problem remain? Go to step 32. The problem is solved. Step 32 Check the HPT transport rollers for misalignment, wear, damage, and contamination. Are the rollers properly installed and free of wear, damage, and contamination? Go to step 34. Go to step 33. Step 33 Reinstall or replace the rollers. See “HPT transport rollers removal”. Does the problem remain? Go to step 34. The problem is solved. Step 34 Reseat the HPT controller board cables, and then check the cables for damage. Are the cables free of damage? Go to step 36. Go to step 35. Step 35 Replace the cables. See “HPT controller board removal”. Does the problem remain? Go to step 36. The problem is solved. Step 36 Replace the controller board. See “HPT controller board removal”. Does the problem remain? Go to step 37. The problem is solved. Step 37 Replace the HPT. Does the problem remain? Contact the next level of support. The problem is solved.

← Xem tất cả mã lỗi Lexmark CX860de

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie