Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 121.07...121.24 — Lexmark M5150

Code: 121.07...121.24

Description: 121.07 Fuser has been on for more than allowed after a gap blowout, and the temperature is still too cold 121.08 Fuser was under temperature when page was in fuser 121.20 Fuser undertemp during steady state control 121.22 Fuser did not warm enough to start line voltage detection 121.23 Fuser took too long to heat to line detection temperature 121.24 Fuser never reached fuser detection temperature
Remedy: Step 1 Ensure the cable for socket “J24” on the controller board is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connections. Go to step 2.
Step 2 Reset the machine. Does the error continue? Replace the fuser drive motor. See “Fuser drive motor removal”. Go to step 3. Problem resolved
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.