Code: 140.10...140.80
Description: 140.10 Transport motor halls not detected. 140.20 Transport motor took too long to stop. 140.30 Transport motor unable to lock (before motor ID). 140.40 Transport motor overspeed detected. 140.60 Transport motor unable to lock (after motor ID). 140.70 Transport motor out of lock detected. 140.80 Transport motor excessive PWM or overtemp.
Remedy: Step 1 Remove the main drive gearbox and check for any debris. Is it free of debris? Go to step 2. Remove the debris.
Step 2 Check the gears of main drive gearbox for wear or damage. Are they free of wear or damage? Go to step 3. Replace the main drive gearbox. See “Main drive gearbox removal”.
Step 3 Check the main drive motor for proper operation: a Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. b POR into the Diagnostics menu and perform a feed test: Diagnostics Menu > Input Tray Tests > Feed Test > Select any input source c Check if the main drive motor rotates when doing the feed test. Does it rotate when doing the feed test? Replace the controller board. See “Controller board removals”. Replace the main drive gearbox. See “Main drive gearbox removal”.
Step 2 Check the gears of main drive gearbox for wear or damage. Are they free of wear or damage? Go to step 3. Replace the main drive gearbox. See “Main drive gearbox removal”.
Step 3 Check the main drive motor for proper operation: a Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. b POR into the Diagnostics menu and perform a feed test: Diagnostics Menu > Input Tray Tests > Feed Test > Select any input source c Check if the main drive motor rotates when doing the feed test. Does it rotate when doing the feed test? Replace the controller board. See “Controller board removals”. Replace the main drive gearbox. See “Main drive gearbox removal”.