Code: 201.01
Description: Narrow media sensor is covered during warm up. Input sensor is not covered.
Remedy: Step 1 Check the narrow media sensor cable JNRW1 for proper connection. Is it properly connected? Go to step 2. Reseat the cable.
Step 2 POR into the Diagnostics menu and perform a sensor test: Diagnostics Menu > Base Sensor Test > Narrow Media Does the sensor state on the control panel display change when it is toggled? Go to step 3. Replace the narrow media sensor. See “Narrow media/bin full sensor removal”.
Step 3 Check the redrive rollers for damage. Are they free of damage? Go to step 4. Replace the redrive assembly. See “Redrive assembly removal”.
Step 4 Does the error remain? Contact the next level of support. The problem is solved.
Step 2 POR into the Diagnostics menu and perform a sensor test: Diagnostics Menu > Base Sensor Test > Narrow Media Does the sensor state on the control panel display change when it is toggled? Go to step 3. Replace the narrow media sensor. See “Narrow media/bin full sensor removal”.
Step 3 Check the redrive rollers for damage. Are they free of damage? Go to step 4. Replace the redrive assembly. See “Redrive assembly removal”.
Step 4 Does the error remain? Contact the next level of support. The problem is solved.