Mã lỗi 121.07...121.37 — Lexmark MS312

Code: 121.07...121.37

Description: 121.07 Fuser has been on for more than allowed after a gap blowout, and the temperature is still too cold. 121.08 Fuser was under temp when page was in fuser. 121.20 Fuser undertemp during steady state control. Can ocurr in printing or standby modes. 121.22 Fuser did not warm enough to start line voltage detection. 121.23 Fuser took too long to heat to line detection temp. 121.24 Fuser never reached detection temperature. 121.25 After line voltage detection, control did not roll over to steady state control in time. 121.26 Failed to reach temperature during warm up. 121.28 Failed to reach EP warm up temperature in time. 121.29 Fuser failed to reach pre.heat temperature for motor start during warm up. 121.30 Fuser failed to reach printing temperature by the time a page reached the fuser. 121.31 Fuser is too hot. Global overtemp check. 121.32 Open fuser main thermistor. 121.33 Open fuser edge thermistor. 121.34 Open fuser backup roll thermistor. 121.35 Attempting to POR after receiving a 121.34. 121.36 Fuser did not heat to allow compression jog. 121.37 Fuser heated faster than allowed during line voltage detection.
Remedy: 1 Restore the engine settings to their defaults: Diagnostics Menu > Printer Setup > Defaults 2 Restore the EP setup settings to their defaults: Diagnostics Menu > EP Setup > Defaults
Step 1 • Check the fuser cables JTHERM1 and JEXIT for proper connection to the controller board. • Check the cable PCN5 for proper connection to the power supply. Are they properly connected? Go to step 2. Reseat the cables.
Step 2 Are the cables JTHERM1, JEXIT and PCN5 free of damage? Go to step 3. Replace the fuser. See “Fuser removal”.
Step 3 a Turn off the printer. b Remove the rear door and cover. c Disconnect the fuser cable connected to PCN5 of the power supply. d Check for approximate correct resistance on the fuser cable: • 220V fuser—43 ohms • 110V fuser—10 ohms • 100V fuser—8 ohms Is the resistance equal to any of the above values? Perform an LVPS service check. See “LVPS service check”. Replace the fuser. See “Fuser removal”.
Step 4 Check the fuser rollers, belts and gears for damage and debris. Are they free of damage and debris? Perform a cooling fan service check and LVPS service check. See “171.xx Cooling fan service check” and “LVPS service check”. Replace the fuser. See “Fuser removal” on

← Xem tất cả mã lỗi Lexmark MS312