Code: 200.09...200.15
Description: 200.09 Printhead did not receive proper motor feedback to start laser servo. 200.10 Printhead motor not locked when media reaches the input sensor. 200.11 Printhead motor fell out of lock after page reaches the input sensor. 200.12 Printhead was not ready for media. 200.13 Media at input sensor is not the next media to be imaged. 200.14 Media reached the input sensor before EP was ready. 200.15 Image data did not start on time.
Remedy: Step 1 Check the LSU cables for proper connection. Are they properly connected? Go to step 2. Reseat the cables.
Step 2 Inspect the LSU cables and connectors. Are they free of damage? Go to step 3. Replace the LSU. See “Laser scanning unit (LSU) removal”.
Step 3 Check the input sensor cable for proper connection. Is it properly connected? Go to step 4. Reseat the cable.
Step 4 POR into the Diagnostics menu and perform a feed test: Diagnostics Menu > Input Tray Tests > Feed Tests > Tray 1 Does it pass the test? Go to step 5. Replace the LSU. See “Laser scanning unit (LSU) removal”.
Step 5 POR into the Diagnostics menu and perform a sensor test: Diagnostics Menu > Base Sensor Test > Input Does the sensor state on the control panel display change when it is toggled? Go to step 6. Replace the input sensor. See “Duplex sensor and input sensor removal”.
Step 6 Check the controller board for any damage. Is it free of damage? Go to step 7. Replace the controller board. See “Controller board removals”.
Step 7 Does the error remain? Contact the next level of support.
Step 2 Inspect the LSU cables and connectors. Are they free of damage? Go to step 3. Replace the LSU. See “Laser scanning unit (LSU) removal”.
Step 3 Check the input sensor cable for proper connection. Is it properly connected? Go to step 4. Reseat the cable.
Step 4 POR into the Diagnostics menu and perform a feed test: Diagnostics Menu > Input Tray Tests > Feed Tests > Tray 1 Does it pass the test? Go to step 5. Replace the LSU. See “Laser scanning unit (LSU) removal”.
Step 5 POR into the Diagnostics menu and perform a sensor test: Diagnostics Menu > Base Sensor Test > Input Does the sensor state on the control panel display change when it is toggled? Go to step 6. Replace the input sensor. See “Duplex sensor and input sensor removal”.
Step 6 Check the controller board for any damage. Is it free of damage? Go to step 7. Replace the controller board. See “Controller board removals”.
Step 7 Does the error remain? Contact the next level of support.