Code: 132.01...132.34
Description: 132.01 TDS baseline too low. 132.02 TDS baseline too high. 132.03 TDS baseline excessive range. 132.16 TDS calibration at maximum. 132.17 TDS calibration too low. 132.18 TDS calibration too close to baseline. 132.32 PC drum measurement too high. 132.33 PC drum measurement too different from calibration. 132.34 PC drum measurement too close to baseline.
Remedy: Step 1 Remove the transfer roll, and check for loose toner blocking the toner density sensor. Is it free of loose toner? Go to step 2. Clean the sensor.
Step 2 Check the toner density sensor for proper operation: a Lower the ACM assembly. b Move the toner density sensor wiper from left to right. Does it move freely? Go to step 3. Reinstall the wiper properly. If it still cannot move freely, replace the toner density sensor. See “Toner density sensor removal”.
Step 3 Check the toner density sensor cable for proper connection to the controller board. Is it properly connected? Go to step 4. Reseat the cable.
Step 4 Check the toner density sensor cable for damage and pinch points. Is it free of damage? Replace the controller board. See “Controller board removals”. Replace the toner density sensor. See “Toner density sensor removal”.
Step 2 Check the toner density sensor for proper operation: a Lower the ACM assembly. b Move the toner density sensor wiper from left to right. Does it move freely? Go to step 3. Reinstall the wiper properly. If it still cannot move freely, replace the toner density sensor. See “Toner density sensor removal”.
Step 3 Check the toner density sensor cable for proper connection to the controller board. Is it properly connected? Go to step 4. Reseat the cable.
Step 4 Check the toner density sensor cable for damage and pinch points. Is it free of damage? Replace the controller board. See “Controller board removals”. Replace the toner density sensor. See “Toner density sensor removal”.