Code: 344.57, 344.58, 344.59
Description: 344.57 Motor 3 motor no first encoder 344.58 Motor 3 motor stop error 344.59 Motor 3 PWM underflow (motor overspeed)
Remedy: Step 1 Check the cable J11 on the option tray controller card. Is it properly connected? Go to step 2. Reseat the cable.
Step 2 a Remove the option tray insert and bypass the tray present sensor. b POR into the Diagnostics Menu and perform a feed test: Diagnostics Menu > Feed Test > choose an option tray c Check the ACM for proper operation. Does the ACM freely rotate three times before displaying a jam message? Go to step 3. Replace the ACM assembly. See “ACM assembly removal”.
Step 3 Is the ACM gear free of wear or damage? Contact the next level of support. Replace the ACM assembly. See “ACM assembly removal”.
Step 2 a Remove the option tray insert and bypass the tray present sensor. b POR into the Diagnostics Menu and perform a feed test: Diagnostics Menu > Feed Test > choose an option tray c Check the ACM for proper operation. Does the ACM freely rotate three times before displaying a jam message? Go to step 3. Replace the ACM assembly. See “ACM assembly removal”.
Step 3 Is the ACM gear free of wear or damage? Contact the next level of support. Replace the ACM assembly. See “ACM assembly removal”.