Code: 332.54, 332.55, 332.56
Description: 332.54 Motor 2 (Separator/Passthru) Motor no first encoder 332.55 Motor 2 (Separator/Passthru) motor stop error 332.56 Motor 2 (Separator/Passthru) PWM underflow (motor overspeed)
Remedy: Step 1 a Remove the option tray insert. b Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Does it move freely, and is it free of wear or damage? Go to step 2. Replace the tray.
Step 2 Check the cable J10 on the option tray controller card. Is it properly connected and free of damage? Go to step 3. Replace the tray.
Step 3 Check the separator roll assembly for wear or damage. Is it free of wear or damage? Contact the next level of support. Replace the separator roll assembly. See “Separator roll assembly removal”.
Step 2 Check the cable J10 on the option tray controller card. Is it properly connected and free of damage? Go to step 3. Replace the tray.