Mã lỗi 5800 — Brother MFC8912DW

Code: 5800

Description: Any of error codes 6A00 to 6F00, 7600, 7800, DD00,DE00, or E200 (fuser unit error) occurred when the power switch was turned ON or sleep mode was released.
Causes: 1 Connection failure of the fuser unit harnesses. 2 Connection failure of the eject sensor PCB harness. 3 Fuser unit failure. 4 Eject sensor PCB failure. 5 Low-voltage power supply PCB failure. 6 Main PCB failure.
Remedy: 1 Connection failure of the fuser unit harnesses Check the connection of fuser unit harnesses, and reconnect them if necessary. 2 Connection failure of the eject sensor PCB harness Check the connection of the eject sensor PCB harness, and reconnect it if necessary. 3 Fuser unit failure Replace the fuser unit. 4 Eject sensor PCB failure Refer to "1.3.10 Check sensor operation (function code: 32)" in Chapter 5 to check the sensor operation. If the sensor operation is faulty, replace the eject sensor PCB ASSY. 5 Low-voltage power supply PCB failure Replace the low-voltage power supply PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY.