Mã lỗi 172.03...173.07 — Lexmark MS710

Code: 172.03...173.07

Description: 172.03 Cartridge cooling fan took too long to ramp up 172.04 Cartridge cooling fan under speed or stalled during speed adjustment state 172.05 Cartridge cooling fan over speed during speed adjustment state 172.06 Cartridge cooling fan capture data is invalid and speed control is at maximum in fan control idle state 172.07 Cartridge cooling fan capture data is invalid and speed control is at maximum in fan control adjustment state 173.03 LVPS cooling fan took too long to ramp up 173.04 LVPS cooling fan under speed or stalled during speed adjustment state 173.05 LVPS cooling fan over speed during speed adjustment state 173.06 LVPS cooling fan capture data is invalid and speed control is at maximum in fan control idle state 173.07 LVPS cooling fan capture data is invalid and speed control is at maximum in fan control adjustment state
Remedy: Step 1 Ensure the LVPS cooling fan cable is properly connected. Is the above cable properly connected? Go to step 2. Reseat the connection.
Step 2 Reset the machine. Does the error continue? Replace the LVPS fan with cable. Go to step 3. Problem resolved.
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.