Code: 31.60...31.65
Description: 31.60 Imaging unit smart chip error 31.61 Imaging unit I2C packet time-out 31.62 Imaging unit I2C packet has been sent, but code timed-out on receiving the data (callback) 31.63 Imaging unit security error in the send challenge sequence 31.64 Imaging unit ROM signature error 31.65 Imaging unit stuck or busy; status register and/or CRI Arbiter register report busy)
Remedy: Step 1 Ensure that the imaging unit is installed properly. Is the imaging unit properly installed? Go to step 2. Reinstall the imaging unit properly.
Step 2 Remove the imaging unit and install a different unit. Does the error remain? Go to step 3. Problem resolved.
Step 3 Ensure the cable for socket "IMAG UNIT" on the controller board is properly connected. Is the above cable properly connected? Go to step 4. Reseat the connection or replace the cable. Go to step 4.
Step 4 Ensure the imaging unit smart chip contact with cable is free from damage. Is the imaging unit smart chip contact with cable free from damage? Go to step 5. Replace the imaging unit smart chip contact with cable. Go to step 5.
Step 5 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
Step 2 Remove the imaging unit and install a different unit. Does the error remain? Go to step 3. Problem resolved.
Step 3 Ensure the cable for socket "IMAG UNIT" on the controller board is properly connected. Is the above cable properly connected? Go to step 4. Reseat the connection or replace the cable. Go to step 4.
Step 4 Ensure the imaging unit smart chip contact with cable is free from damage. Is the imaging unit smart chip contact with cable free from damage? Go to step 5. Replace the imaging unit smart chip contact with cable. Go to step 5.
Step 5 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.