Code: 200.34
Description: Short media detected.
Remedy: Step 1 Check the sensor (input) for proper operation. a Enter the diagnostic mode. b Select Base sensor test. c Observe the line item control panel door interlock. Does the display on the control panel change every time the sensing area of the above sensor is interrupted or blocked? Go to step 3. Go to step 2.
Step 2 Check the above sensor for proper connection. Is the above sensor connected properly? Replace the sensor (control panel door interlock). Go to step 3. Replace the connection. Go to step 3.
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem solved.
Step 2 Check the above sensor for proper connection. Is the above sensor connected properly? Replace the sensor (control panel door interlock). Go to step 3. Replace the connection. Go to step 3.
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem solved.