Code: 202.16...202.22
Description: 202.16 Page at fuser nip before fuser started ramping toward desired area. Indicates code may be receiving more hall interrupts than intended 202.17 Page at fuser nip before fuser reached acceptable operating temperature. Page arrived at fuser earlier than expected, so it was probably staged 202.22 Cartridge Motor.Motor under.speed error. Motor made it to closed loop at a steady state, but then detected speed was below threshold
Remedy: Step 1 Check the fuser drive motor and the socket “J24” on the controller board for proper connection. Is the main drive motor properly connected? Replace the fuser drive motor. See “Fuser drive motor removal”. Go to step 2. Reseat the connection.
Step 2 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem solved.