Code: 126.01, 126.02
Description: 126.01 Line frequency outside operating range of device. 126.02 No line frequency detected.
Remedy: 1 Check the power cord for continuity. Replace if necessary. 2 Make sure the nominal voltage source is within specification.
Step 1 Check if the power supply cable is properly connected to the controller board. Is it properly connected? Go to step 2. Reseat the cables.
Step 2 a Turn off the printer. b Remove the power cord. c Measure the resistance between terminals A and D of the power supply socket. Is the resistance approximately 30 ohms? Contact your next level of support. Replace the power supply. See “Power supply removal”.
Step 1 Check if the power supply cable is properly connected to the controller board. Is it properly connected? Go to step 2. Reseat the cables.
Step 2 a Turn off the printer. b Remove the power cord. c Measure the resistance between terminals A and D of the power supply socket. Is the resistance approximately 30 ohms? Contact your next level of support. Replace the power supply. See “Power supply removal”.