Code: 31.21...31.25
Description: 31.21 Capactive Toner Level Sensing (CTLS) reading out of range. 31.22 Excessive CTLS noise. 31.23 Abrupt change detected in CTLS reading. 31.25 CTLS calibration capacitor reading is too low
Remedy: Step 1 Check for loose toner blocking the CTLS. Is it free of any loose toner? Go to step 2. Clean the CTLS.
Step 2 • Check the cable PCN3 for proper connection to the power supply. • Check the CTLS cable for proper connection to the controller board. Are they properly connected? Go to step 3. Reseat the cables.
Step 3 Check the cable PCN3 and CTLS cable for damage. Are they free of damage? Replace the controller board. See “Controller board removals”. Replace the printer.
Step 2 • Check the cable PCN3 for proper connection to the power supply. • Check the CTLS cable for proper connection to the controller board. Are they properly connected? Go to step 3. Reseat the cables.
Step 3 Check the cable PCN3 and CTLS cable for damage. Are they free of damage? Replace the controller board. See “Controller board removals”. Replace the printer.